Mindray BeneHeart L2-A
Fully automatic AED with a 4.3″ colour touchscreen.
The L2-A pairs a 4.3" colour touchscreen with fully automatic shock delivery. Animated step guidance runs alongside voice prompts and a real-time metronome, with compression feedback displayed during the rescue rather than reviewed after it.
Animated on-screen guidance
A 480 × 272 colour display pairs animation with voice prompts and a metronome, with Auto, Outdoor and Indoor brightness modes for readability in the field.
CPR feedback on screen
Depth and rate guidance at 5–6 cm and 100–120 per minute.1 Rate is measured to ±3 cpm from the electrode pads, or ±2 cpm with the MR66 CPR sensor.
AED-Alert 2.0
Battery status, pad expiry, location and self-test results report over 4G or Wi-Fi across an entire fleet, GDPR-compliant throughout.1
Mindray L1 vs L2
| Specification | Mindray L1 | Mindray L2 |
|---|---|---|
| Operation | Semi-auto / Auto | Semi-auto / Auto |
| Display | 1.96" dot-matrix LCD | 4.3" colour touchscreen |
| Rescuer guidance | Voice prompts + CPR metronome | Animation + voice + CPR feedback |
| Capacity | 400 shocks @ 200 J | 350 shocks @ 200 J |
| Operating time | ≥ 15 hours | ≥ 12 hours |
| Energy | Up to 360 J escalating | Up to 360 J escalating |
| Charge time | 0 s effective — pre-charged during analysis | 0 s effective — pre-charged during analysis |
| Weight | 1.9 kg | 1.9 kg |
| Dimensions | 196 × 191 × 65.5 mm | 196 × 191 × 65.5 mm |
| Ingress rating | IP55 · 1.5 m 6-surface drop | IP55 · 1.5 m 6-surface drop |
| Models Available | ||
| Auto | L1-A | L2-AThis device |
| Semi | L1-S | L2-S |
| Auto + CPR sensor | L1-A-CPR | — |
| Semi + CPR sensor | — | L2-S-CPR |
Figures from the Mindray BeneHeart L1 / L2 datasheet and the L series operator’s manual (H-046-028014-00). Specifications are subject to change without notice.
Mindray L Series AEDs
Zero Compromise
The Mindray BeneHeart L2-A is available in Australia through Aero Healthcare.
- Mindray BeneHeart L Series brochure (L1 / L2), Shenzhen Mindray Bio-Medical Electronics Co., Ltd. Source for 38% smaller / 22% lighter, up to 360J escalating energy, CPR Coach depth and rate guidance, ResQNavi™ and AED-Alert 2.0.
- Mindray QShock™ Plus — L series AED defibrillation technology. Source for the five-second post-CPR re-shock and comparative shock-cycle timing.
- Mindray BeneHeart L1 / L2 Datasheet. Source for 1.9 kg weight, pre-shock pause under 5 s, IP55, 1.5 m 6-surface drop, 5-year battery and pad standby, and all technical specifications.
- European Resuscitation Council Guidelines 2025. Each minute of delay to defibrillation is associated with a higher probability of failure to terminate VF and lower probability of survival to discharge.
- Tang H, Wu R, Yin L, et al. Escalating vs Fixed Energy Defibrillation in Out-of-Hospital Cardiac Arrest Ventricular Fibrillation. JAMA Netw Open. 2025;8(4):e257411.
Distributed in Australia by Aero Healthcare. Specifications may vary based on installation environment and usage conditions. For details, consult the manual.
This product is not a substitute for direct medical attention from a healthcare practitioner. Always read the label and follow the directions for use.



Introducing the NEW Mini Modulator - perfectly sized for taking on your next adventure!

1 review for MINDRAY L2 Fully-Automatic Defibrillator